Calculators

Field calculations, done properly. No account. No number you enter leaves your browser.

100 tools. Matches the tool name, its description, and the standard it cites.

Schedules & PM

Primavera P6 exports — converted, compared, sliced, and assessed.

P6 → Excel Converter

Drop a Primavera P6 .xer export and get a clean workbook — Activities, Relationships, WBS, a P6-style banded view.

Open

Schedule Health Check

DCMA 14-point assessment on an XER — every check, threshold, pass/fail, and the activities to fix.

Open

Schedule Comparison

Previous vs current XER — added, deleted, changed and renumbered or split activities, logic, finish slips ranked, critical-path changes, and the change log written for you.

Open

Look-Ahead

2- to 8-week look-ahead from the data date, by week and area, with what each activity is waiting on.

Open

Labor Histogram

Remaining or planned hours by week and resource, the peak, FTEs, the cumulative curve, unassigned activities.

Open

XER Viewer

Open a P6 XER as a Gantt without P6 — filter by WBS, activity codes, float and dates, critical work marked, share the view as a link, print.

Open

Circuits & Conductors

Load calculations and sizing the wire — Article 220, drop, ampacity, terminations, grounding, transformers, motors, fault current.

Voltage Drop

Resistance or impedance method (Table 8 K, or Table 9 with power factor); size, drop, or max length.

Open

Ampacity & Derating

Table 310.16 with ambient, conductor count, and termination limits.

Open

Wire Sizing

Minimum conductor for a load: ampacity, terminations, continuous load, and voltage drop.

Open

Transformer

Full-load currents, Table 450.3(B) protection, and kVA for a load.

Open

Grounding Conductors

Table 250.122 EGC by device, 250.122(B) upsizing, Table 250.66 GEC by service conductors.

Open

Motor Circuits

Table FLC, 125 % conductors, 430.52 device by type with Exception 1, nameplate overloads, disconnect, EGC; feeders for several motors.

Open

Fault Current

Transformer kVA and %Z, utility contribution, conductor runs on Table 9 impedances, motor contribution — kA at each point.

Open

Service & Feeder

From a calculated load to conductors, device, grounding electrode conductor or EGC, and bonding jumper in one pass — with the 310.12 dwelling rule.

Open

Dwelling Load (220)

Standard and optional methods side by side, existing-dwelling check, EVSE, neutral, service size — line by line with the section.

Open

Commercial Load (220)

Lighting by occupancy with demand factors, receptacles, signs and show windows, kitchen, motors, HVAC — calculated load, continuous portion, neutral, service size.

Open

Multifamily Load (220)

Part III and the 220.84 optional method side by side for N identical units, the 8 kW cooking exception, the 220.85 duplex rule, three-phase range and dryer counting, house loads, neutral, service size.

Open

Schools, Restaurants & Existing Loads (220)

Table 220.86 by VA per square foot, Table 220.88 all-electric or not, and 125 % of measured demand plus the new load against the existing rating.

Open

EV Charging Circuit

The 125 % continuous rule for the device and conductors, the EGC, charge-time, and the 220.57 service load — with the EVEMS allowance.

Open

PV Strings & Source Circuits

Maximum string voltage from the module's coefficient at the site's record low, 125 % currents, conductor by the larger of the two 690.8(B) rules, device by 690.9.

Open

HVAC Equipment Circuit

Minimum circuit ampacity and maximum overcurrent protection from the compressors, fans, and heat — then the wire and EGC.

Open

Transformer Inrush

First-half-cycle inrush from the multiple you enter against the breaker's instantaneous trip or the fuse's melt curve, with the 450.3(B) context.

Open

Data Center Power & Cooling Chain

IT load → UPS kVA and input → feeder amps and devices → heat, tons, cooling units with N+1 → CFM and chilled-water GPM → facility power at the PUE.

Open

VFD Circuit

Conductors at 125 % of the drive's rated input current (430.122), motor conductors per 430.22, device by the drive's listing and 430.52, EGC.

Open

Lighting Layout & Circuits

Fixtures from footcandles, lumens, CU, and light loss factor; room cavity ratio; watts and W/ft²; circuits at the continuous-load rating (80 % of a 15 A or 20 A breaker).

Open

Busway Load & Drop

Loading at the feed against the rating and the voltage drop tap by tap from the manufacturer's R and X per 1000 ft.

Open

Raceways, Boxes & Pulls

Fill, bends, boxes, tray, and getting the cable in.

Conduit Bend Total

Sum the bends between pull points against 360° or a 270° spec.

Open

Conduit Fill

Chapter 9 Tables 1, 4, 5 — check a size, find the smallest, or count what fits.

Open

Box Fill

314.16 volume count — conductors, devices, clamps, studs, grounds.

Open

Cable Tray Fill

392.22 — multiconductor cables or single conductors in ladder and ventilated tray.

Open

Conduit Bending

Offsets, saddles, 90° stubs, segmented bends, kicks, gain — marks to the sixteenth.

Open

Cable Pull

Pulling tension and sidewall pressure through the run — both directions.

Open

Pull Box Sizing

314.28 — straight, angle, and U pulls from the raceway trade sizes.

Open

Power & Basics

Ohm's law, power, power factor, harmonics, UPS batteries, and unit conversions.

Ohm's Law

Any two of volts, amps, ohms, watts → all four.

Open

Power

Watts, volts, amps, and power factor — single- or three-phase.

Open

Power Triangle

kW, kVA, kVAR, and power factor from any two.

Open

Power Factor Correction

Capacitor kVAR to reach a target power factor.

Open

Conductor Size Conversions

AWG and kcmil to circular mils, mm² and diameter.

Open

K-Factor

Harmonic loads by type or measured spectrum → K-factor, THDi, the K-rated transformer, and the neutral warning.

Open

UPS Battery Sizing

Load, runtime, DC bus, chemistry, aging and temperature factors → Ah, end voltage, discharge current, kW per cell.

Open

Motor Formulas

120 f / P, slip, T = 5252 hp / rpm, hp from torque, kW and current at PF and efficiency, NEMA frame shaft height, belt ratio.

Open

Battery Bank Sizing

Daily watt-hours from a load list, days of autonomy, depth of discharge, inverter efficiency, cold and aging margins → Ah, batteries in series and parallel, kWh, recharge time.

Open

Systems & Code Checks

Working space, standby power, and panel balance.

Working Space

Table 110.26(A)(1) depth by voltage and condition, width, height, dedicated space, egress rules.

Open

Generator Sizing

Load schedule with starting methods and NEMA codes, step loading, derates, nonlinear oversizing, standard kW.

Open

Panel Balance

Phase totals, imbalance, neutral current, and a rebalanced assignment with the moves.

Open

Flexible Cords & Temp Power

The cord gauge for a load over a length — Table 400.5(A)(1) ampacity with the bundling and ambient factors, and the drop that stalls the tool.

Open

Procurement & Prefab

Cut lists, reels, buy quantities, and lead times.

Cut Optimizer

Strut, conduit, tray, all-thread — fewest sticks, least waste, kerf and remnants, buy list.

Open

Reel Optimizer

Pull schedule → reels to buy, cut plan per reel, scrap, weight — or cut to length.

Open

Buy Quantity

Takeoff → sticks, reels, boxes with waste factors, rounding, and cost.

Open

Lead-Time Backward Pass

Install date → on-site, ship, release, approval, submit-by — working days, holidays, review cycles.

Open

Civil & Site

Concrete for duct banks, pads, bases, formwork, thrust blocks, rebar, trenches, and the holes they go in.

Duct Bank Concrete

Encasement by section: conduit matrix or trench dims, conduits deducted by OD, waste, yards, trucks, rebar.

Open

Pads, Bases & Backfill

Equipment pads with rebar mats, round or square bases, manhole excavation, spoil, and backfill tonnage.

Open

Formwork Pressure

Lateral pressure on wall and column forms from height, placement rate, temperature, unit weight, and mix chemistry.

Open

Thrust Block

Thrust from test pressure and fitting geometry, bearing area from the allowable soil bearing and a safety factor.

Open

Rebar Takeoff

Bars per direction from spacing, laps where the run exceeds stock, sticks, weight, and tons — one way or a mat, one or two layers.

Open

Trench Excavation & Sloping

Cut and spoil with the OSHA 1926 Subpart P slope for the soil type, swell, truck loads, bedding, pipe displacement, compacted backfill, and the protective-system triggers.

Open

Earthwork — Cut & Fill, Piles, Tonnage, Grade

Grid-method cut and fill with swell and shrinkage, cone / windrow / flat-top stockpiles to yards and tons, aggregate or asphalt tonnage for an area and depth, grade percent / ratio / degrees.

Open

Logistics

Lifts, rigging paths, truck loads, and the paper that goes on the truck.

Rigging

Sling tension by angle and hitch, offset-CG leg loads, hardware utilization, crane-chart check with deductions, outrigger pad size.

Open

Gear Path Check

Skid through every door, corridor, ramp, elevator, and floor on the route — clearances, turns, grades, floor and point loads.

Open

Truck Load

Cube, weight, pallet positions, which truck and how many, LTL vs FTL, density-based freight class.

Open

Packing List & BOL

Pieces by kit or work package → a printable packing list and straight bill of lading with classes and totals.

Open

Crane Pick in Wind

Wind pressure and force on the load from speed, sail area, and drag coefficient; percent of chart with deductions; side-load and stop-work checks.

Open

Safety

NFPA 70E boundaries and PPE, incident rates, noise dose, fall clearance, heat stress, NIOSH lifting, glove and grounding logs, and methods of procedure.

Shock & Arc-Flash (70E)

Shock approach boundaries and the arc-flash PPE category method — refuses when the equipment is outside the table's parameters.

Open

TRIR / DART

OSHA incident rates on the 200,000-hour basis, with headroom against a target TRIR.

Open

Rubber Glove Log

ASTM D120 class by exposure voltage, 6-month retest dates, air-test record, printable log.

Open

Assured Grounding Log

OSHA's 3- and 6-month test intervals plus the other triggers, test records for cords, tools, and receptacles — colour coding is one permitted record, not a requirement.

Open

MOP Builder

A data-center MOP laid out with risk level, prerequisites, PPE, hazards, steps with hold points, back-out, contacts, approvals — print or share by link.

Open

Noise Dose

Daily noise dose and 8-hour TWA from each sound level and duration — OSHA 5 dB exchange or NIOSH 3 dB.

Open

Fall Clearance

Lanyard length, deceleration, harness stretch, D-ring height, and margin against the anchor height — with the 6 ft free-fall check.

Open

Heat Index & WBGT

Heat index from temperature and humidity with the NWS categories, or WBGT from natural wet-bulb, globe, and dry-bulb readings.

Open

NIOSH Lifting Equation

RWL and lifting index from H, V, D, A, frequency, duration, and coupling — the Applications Manual's tables, verified against its worked examples.

Open

Scaffold Loading

Platform load by duty (25 / 50 / 75 psf) vs the people and material, Appendix A plank spans, leg load (the scaffold's own weight plus 4 × the load on that leg) against the frame capacity, and the 4:1 height-to-base tie rule.

Open

Field Logs & Records

Torque verification, insulation resistance, and the panel directory — the paper the inspector reads.

Torque Lookup & Verification Log

Recommended torque for Allen / square-drive and small slotted screws when the manufacturer gives none, and a printable log of every termination torqued.

Open

Insulation Resistance Log

Megger readings corrected to 40 °C, pass/fail against the minimum you set, PI and DAR, printable log.

Open

Circuit Directory & Panel Labels

Numbers the circuits odd-left / even-right with multi-pole devices in place, checks 408.4(A) identifications, prints the directory and a label sheet, totals the phases.

Open

Low Voltage

Fiber loss budgets, PoE budgets, decibel arithmetic, and comm cable conduit fill.

Fiber Loss Budget

Cable, connector, and splice loss against the transceiver's power budget and your margin — and how far the optics reach.

Open

PoE Budget

Adds up the PSE power the switch allocates per class and device count against its budget, with cable loss and port count.

Open

dB & RF Link

dBm to mW, a gain/loss chain through cable and splitters, VSWR, return loss and mismatch loss, and free-space path loss.

Open

Comm Cable Conduit Fill

Fill of a conduit, the smallest conduit for a bundle, or how many of one cable fit — TIA-569 limits on the verified raceway dimensions, jam-ratio check.

Open

Rack-U Planner

Sum the U, weight, watts, and plugs of the equipment against the rack, the PDUs at their continuous-load rating (80 % of the plug rating unless the PDU is listed for 100 %), and the outlet count — with the single-side check for A/B feeds.

Open

Reference & Jobsite

The jobsite calculator, unit and fastener conversions, AC to DC, NEMA plugs and enclosures, and wire colour codes.

Jobsite Calculator

Feet-inch-fraction math, right triangles and pitch, circles and arcs, and a running tape — snapped to 1/16 in.

Open

Unit & Fastener Converter

Every unit a job site argues about, plus inch and metric bolt sizes, threads per inch, pitch, and wrench sizes.

Open

AC to DC Converter

Sine-wave RMS, peak and average, rectifier DC output with diode drops and ripple, inverter battery current and run time, W to VA.

Open

NEMA Plug & Receptacle Finder

Search NEMA WD 6 configurations (5-15 to L23-30) by voltage, amps, locking, or number — poles, wires, and what each is for.

Open

NEMA Enclosure Types & IP

Pick the NEMA type for the location, see what each type protects against, decode an IP code — with NEMA's IEC cross-reference.

Open

Wire Color Codes

Conductor identification by code and by convention: NEC 200.6 / 250.119 / 110.15, North American phase colours, IEC 60446, BS 7671 old and new, CE Code, AS/NZS 3000.

Open

Electrical Formula Sheet

Sixty-plus formulas by group with a search — the reference card behind the calculators.

Open

HVAC

Ducts, air, and heat.

Duct Sizer

Round and rectangular sizing by friction rate and velocity, a size check, cfm to Btu/h, psychrometrics.

Open

Fan Laws, Grilles & Hydronic Flow

New CFM, static pressure, and BHP at a new speed; grille face area from CFM and velocity; GPM from BTU/h and ΔT with glycol correction and pipe velocity.

Open

Psychrometrics

State point from dry bulb and RH / wet bulb / dew point at the site altitude (ASHRAE formulas); sensible, latent, and total load from CFM and the change.

Open

Plumbing

Pipe hydraulics, slope, and volume.

Pipe Flow & Slope

Hazen–Williams loss and velocity in Sch 40, copper L, PVC; size for a velocity; drain slope, fall, invert; volume and weight.

Open

Glycol Fill

Pipe-by-pipe system volume plus equipment, glycol and water gallons at the concentration, approximate freeze point.

Open

Framing

Stud walls, rafters, and stairs.

Wall, Roof & Stairs

Stud walls with openings, plates, headers, sheathing, board feet; common rafters and cuts; stairs against the IRC limits.

Open

Hips, Valleys, Jacks & Joists

Hip / valley and common lengths from the run, pitch, and overhang, jack rafter common difference and count, and the floor joist, rim, and subfloor takeoff.

Open

Ironwork

Steel weights and takeoffs.

Steel Weight Takeoff

Members by designation (W, S, HP, C, L, HSS, plate, bar, pipe) → weight, tons, pieces; plate weights.

Open

Deck Sheets & Weld Consumables

Deck or grating sheets from the area, coverage width, length, lap, and waste with the weight; electrode or wire pounds for fillet welds by leg, length, and process.

Open

Masonry

Brick, block, mortar, grout, and steel.

Brick & Block Takeoff

Units from the wall and openings, mortar bags, grout yards for cells or full, vertical bars, bond beams, joint reinforcement.

Open

Masonry Ties, Flashing & Weeps

Ties from the veneer area by the 2022 Basic or Enhanced method plus every unsupported edge, flashing lineal feet by level, weeps at the spacing.

Open

Fire Protection

Sprinkler hydraulics and layout.

Sprinkler Hydraulics

Remote-area demand from density and coverage, K-factor flow and pressure, Hazen–Williams in steel, head layout for a room.

Open

Hydrant Flow Test

Flow from the pitot reading and outlet, then the N¹·⁸⁵ supply curve and the flow available at 20 psi.

Open

Members

A whole schedule at once — sign in, then save what you run.

Batch Conductor Sizing · Members

A whole feeder and branch-circuit schedule at once — Excel template in, sized workbook out, saved to your account if you choose.

Open