P6 → Excel Converter
Drop a Primavera P6 .xer export and get a clean workbook — Activities, Relationships, WBS, a P6-style banded view.
OpenField calculations, done properly. No account. No number you enter leaves your browser.
100 tools. Matches the tool name, its description, and the standard it cites.
Primavera P6 exports — converted, compared, sliced, and assessed.
Drop a Primavera P6 .xer export and get a clean workbook — Activities, Relationships, WBS, a P6-style banded view.
OpenDCMA 14-point assessment on an XER — every check, threshold, pass/fail, and the activities to fix.
OpenPrevious vs current XER — added, deleted, changed and renumbered or split activities, logic, finish slips ranked, critical-path changes, and the change log written for you.
Open2- to 8-week look-ahead from the data date, by week and area, with what each activity is waiting on.
OpenRemaining or planned hours by week and resource, the peak, FTEs, the cumulative curve, unassigned activities.
OpenOpen a P6 XER as a Gantt without P6 — filter by WBS, activity codes, float and dates, critical work marked, share the view as a link, print.
OpenLoad calculations and sizing the wire — Article 220, drop, ampacity, terminations, grounding, transformers, motors, fault current.
Resistance or impedance method (Table 8 K, or Table 9 with power factor); size, drop, or max length.
OpenTable 310.16 with ambient, conductor count, and termination limits.
OpenMinimum conductor for a load: ampacity, terminations, continuous load, and voltage drop.
OpenFull-load currents, Table 450.3(B) protection, and kVA for a load.
OpenTable 250.122 EGC by device, 250.122(B) upsizing, Table 250.66 GEC by service conductors.
OpenTable FLC, 125 % conductors, 430.52 device by type with Exception 1, nameplate overloads, disconnect, EGC; feeders for several motors.
OpenTransformer kVA and %Z, utility contribution, conductor runs on Table 9 impedances, motor contribution — kA at each point.
OpenFrom a calculated load to conductors, device, grounding electrode conductor or EGC, and bonding jumper in one pass — with the 310.12 dwelling rule.
OpenStandard and optional methods side by side, existing-dwelling check, EVSE, neutral, service size — line by line with the section.
OpenLighting by occupancy with demand factors, receptacles, signs and show windows, kitchen, motors, HVAC — calculated load, continuous portion, neutral, service size.
OpenPart III and the 220.84 optional method side by side for N identical units, the 8 kW cooking exception, the 220.85 duplex rule, three-phase range and dryer counting, house loads, neutral, service size.
OpenTable 220.86 by VA per square foot, Table 220.88 all-electric or not, and 125 % of measured demand plus the new load against the existing rating.
OpenThe 125 % continuous rule for the device and conductors, the EGC, charge-time, and the 220.57 service load — with the EVEMS allowance.
OpenMaximum string voltage from the module's coefficient at the site's record low, 125 % currents, conductor by the larger of the two 690.8(B) rules, device by 690.9.
OpenMinimum circuit ampacity and maximum overcurrent protection from the compressors, fans, and heat — then the wire and EGC.
OpenFirst-half-cycle inrush from the multiple you enter against the breaker's instantaneous trip or the fuse's melt curve, with the 450.3(B) context.
OpenIT load → UPS kVA and input → feeder amps and devices → heat, tons, cooling units with N+1 → CFM and chilled-water GPM → facility power at the PUE.
OpenConductors at 125 % of the drive's rated input current (430.122), motor conductors per 430.22, device by the drive's listing and 430.52, EGC.
OpenFixtures from footcandles, lumens, CU, and light loss factor; room cavity ratio; watts and W/ft²; circuits at the continuous-load rating (80 % of a 15 A or 20 A breaker).
OpenLoading at the feed against the rating and the voltage drop tap by tap from the manufacturer's R and X per 1000 ft.
OpenFill, bends, boxes, tray, and getting the cable in.
Sum the bends between pull points against 360° or a 270° spec.
OpenChapter 9 Tables 1, 4, 5 — check a size, find the smallest, or count what fits.
Open314.16 volume count — conductors, devices, clamps, studs, grounds.
Open392.22 — multiconductor cables or single conductors in ladder and ventilated tray.
OpenOffsets, saddles, 90° stubs, segmented bends, kicks, gain — marks to the sixteenth.
OpenPulling tension and sidewall pressure through the run — both directions.
Open314.28 — straight, angle, and U pulls from the raceway trade sizes.
OpenOhm's law, power, power factor, harmonics, UPS batteries, and unit conversions.
Any two of volts, amps, ohms, watts → all four.
OpenWatts, volts, amps, and power factor — single- or three-phase.
OpenkW, kVA, kVAR, and power factor from any two.
OpenCapacitor kVAR to reach a target power factor.
OpenAWG and kcmil to circular mils, mm² and diameter.
OpenHarmonic loads by type or measured spectrum → K-factor, THDi, the K-rated transformer, and the neutral warning.
OpenLoad, runtime, DC bus, chemistry, aging and temperature factors → Ah, end voltage, discharge current, kW per cell.
Open120 f / P, slip, T = 5252 hp / rpm, hp from torque, kW and current at PF and efficiency, NEMA frame shaft height, belt ratio.
OpenDaily watt-hours from a load list, days of autonomy, depth of discharge, inverter efficiency, cold and aging margins → Ah, batteries in series and parallel, kWh, recharge time.
OpenWorking space, standby power, and panel balance.
Table 110.26(A)(1) depth by voltage and condition, width, height, dedicated space, egress rules.
OpenLoad schedule with starting methods and NEMA codes, step loading, derates, nonlinear oversizing, standard kW.
OpenPhase totals, imbalance, neutral current, and a rebalanced assignment with the moves.
OpenThe cord gauge for a load over a length — Table 400.5(A)(1) ampacity with the bundling and ambient factors, and the drop that stalls the tool.
OpenCut lists, reels, buy quantities, and lead times.
Strut, conduit, tray, all-thread — fewest sticks, least waste, kerf and remnants, buy list.
OpenPull schedule → reels to buy, cut plan per reel, scrap, weight — or cut to length.
OpenTakeoff → sticks, reels, boxes with waste factors, rounding, and cost.
OpenInstall date → on-site, ship, release, approval, submit-by — working days, holidays, review cycles.
OpenConcrete for duct banks, pads, bases, formwork, thrust blocks, rebar, trenches, and the holes they go in.
Encasement by section: conduit matrix or trench dims, conduits deducted by OD, waste, yards, trucks, rebar.
OpenEquipment pads with rebar mats, round or square bases, manhole excavation, spoil, and backfill tonnage.
OpenLateral pressure on wall and column forms from height, placement rate, temperature, unit weight, and mix chemistry.
OpenThrust from test pressure and fitting geometry, bearing area from the allowable soil bearing and a safety factor.
OpenBars per direction from spacing, laps where the run exceeds stock, sticks, weight, and tons — one way or a mat, one or two layers.
OpenCut and spoil with the OSHA 1926 Subpart P slope for the soil type, swell, truck loads, bedding, pipe displacement, compacted backfill, and the protective-system triggers.
OpenGrid-method cut and fill with swell and shrinkage, cone / windrow / flat-top stockpiles to yards and tons, aggregate or asphalt tonnage for an area and depth, grade percent / ratio / degrees.
OpenLifts, rigging paths, truck loads, and the paper that goes on the truck.
Sling tension by angle and hitch, offset-CG leg loads, hardware utilization, crane-chart check with deductions, outrigger pad size.
OpenSkid through every door, corridor, ramp, elevator, and floor on the route — clearances, turns, grades, floor and point loads.
OpenCube, weight, pallet positions, which truck and how many, LTL vs FTL, density-based freight class.
OpenPieces by kit or work package → a printable packing list and straight bill of lading with classes and totals.
OpenWind pressure and force on the load from speed, sail area, and drag coefficient; percent of chart with deductions; side-load and stop-work checks.
OpenNFPA 70E boundaries and PPE, incident rates, noise dose, fall clearance, heat stress, NIOSH lifting, glove and grounding logs, and methods of procedure.
Shock approach boundaries and the arc-flash PPE category method — refuses when the equipment is outside the table's parameters.
OpenOSHA incident rates on the 200,000-hour basis, with headroom against a target TRIR.
OpenASTM D120 class by exposure voltage, 6-month retest dates, air-test record, printable log.
OpenOSHA's 3- and 6-month test intervals plus the other triggers, test records for cords, tools, and receptacles — colour coding is one permitted record, not a requirement.
OpenA data-center MOP laid out with risk level, prerequisites, PPE, hazards, steps with hold points, back-out, contacts, approvals — print or share by link.
OpenDaily noise dose and 8-hour TWA from each sound level and duration — OSHA 5 dB exchange or NIOSH 3 dB.
OpenLanyard length, deceleration, harness stretch, D-ring height, and margin against the anchor height — with the 6 ft free-fall check.
OpenHeat index from temperature and humidity with the NWS categories, or WBGT from natural wet-bulb, globe, and dry-bulb readings.
OpenRWL and lifting index from H, V, D, A, frequency, duration, and coupling — the Applications Manual's tables, verified against its worked examples.
OpenPlatform load by duty (25 / 50 / 75 psf) vs the people and material, Appendix A plank spans, leg load (the scaffold's own weight plus 4 × the load on that leg) against the frame capacity, and the 4:1 height-to-base tie rule.
OpenTorque verification, insulation resistance, and the panel directory — the paper the inspector reads.
Recommended torque for Allen / square-drive and small slotted screws when the manufacturer gives none, and a printable log of every termination torqued.
OpenMegger readings corrected to 40 °C, pass/fail against the minimum you set, PI and DAR, printable log.
OpenNumbers the circuits odd-left / even-right with multi-pole devices in place, checks 408.4(A) identifications, prints the directory and a label sheet, totals the phases.
OpenFiber loss budgets, PoE budgets, decibel arithmetic, and comm cable conduit fill.
Cable, connector, and splice loss against the transceiver's power budget and your margin — and how far the optics reach.
OpenAdds up the PSE power the switch allocates per class and device count against its budget, with cable loss and port count.
OpendBm to mW, a gain/loss chain through cable and splitters, VSWR, return loss and mismatch loss, and free-space path loss.
OpenFill of a conduit, the smallest conduit for a bundle, or how many of one cable fit — TIA-569 limits on the verified raceway dimensions, jam-ratio check.
OpenSum the U, weight, watts, and plugs of the equipment against the rack, the PDUs at their continuous-load rating (80 % of the plug rating unless the PDU is listed for 100 %), and the outlet count — with the single-side check for A/B feeds.
OpenThe jobsite calculator, unit and fastener conversions, AC to DC, NEMA plugs and enclosures, and wire colour codes.
Feet-inch-fraction math, right triangles and pitch, circles and arcs, and a running tape — snapped to 1/16 in.
OpenEvery unit a job site argues about, plus inch and metric bolt sizes, threads per inch, pitch, and wrench sizes.
OpenSine-wave RMS, peak and average, rectifier DC output with diode drops and ripple, inverter battery current and run time, W to VA.
OpenSearch NEMA WD 6 configurations (5-15 to L23-30) by voltage, amps, locking, or number — poles, wires, and what each is for.
OpenPick the NEMA type for the location, see what each type protects against, decode an IP code — with NEMA's IEC cross-reference.
OpenConductor identification by code and by convention: NEC 200.6 / 250.119 / 110.15, North American phase colours, IEC 60446, BS 7671 old and new, CE Code, AS/NZS 3000.
OpenSixty-plus formulas by group with a search — the reference card behind the calculators.
OpenDucts, air, and heat.
Round and rectangular sizing by friction rate and velocity, a size check, cfm to Btu/h, psychrometrics.
OpenNew CFM, static pressure, and BHP at a new speed; grille face area from CFM and velocity; GPM from BTU/h and ΔT with glycol correction and pipe velocity.
OpenState point from dry bulb and RH / wet bulb / dew point at the site altitude (ASHRAE formulas); sensible, latent, and total load from CFM and the change.
OpenPipe hydraulics, slope, and volume.
Hazen–Williams loss and velocity in Sch 40, copper L, PVC; size for a velocity; drain slope, fall, invert; volume and weight.
OpenPipe-by-pipe system volume plus equipment, glycol and water gallons at the concentration, approximate freeze point.
OpenStud walls, rafters, and stairs.
Stud walls with openings, plates, headers, sheathing, board feet; common rafters and cuts; stairs against the IRC limits.
OpenHip / valley and common lengths from the run, pitch, and overhang, jack rafter common difference and count, and the floor joist, rim, and subfloor takeoff.
OpenSteel weights and takeoffs.
Members by designation (W, S, HP, C, L, HSS, plate, bar, pipe) → weight, tons, pieces; plate weights.
OpenDeck or grating sheets from the area, coverage width, length, lap, and waste with the weight; electrode or wire pounds for fillet welds by leg, length, and process.
OpenBrick, block, mortar, grout, and steel.
Units from the wall and openings, mortar bags, grout yards for cells or full, vertical bars, bond beams, joint reinforcement.
OpenTies from the veneer area by the 2022 Basic or Enhanced method plus every unsupported edge, flashing lineal feet by level, weeps at the spacing.
OpenSprinkler hydraulics and layout.
Remote-area demand from density and coverage, K-factor flow and pressure, Hazen–Williams in steel, head layout for a room.
OpenFlow from the pitot reading and outlet, then the N¹·⁸⁵ supply curve and the flow available at 20 psi.
OpenA whole schedule at once — sign in, then save what you run.
A whole feeder and branch-circuit schedule at once — Excel template in, sized workbook out, saved to your account if you choose.
Open